Accepted | In press

Yan, P., Zamiri, M.S., Marica, F., Nicot, B., Green, D., and Balcom, B.J.
"Temperature-Dependent Magnetic Resonance Relaxation Behaviors in Porous Materials", Physical Review Letters, accepted.

Ansaribaranghar, N., Zamiri, M.S., Romero-Zerón, L., Marica, F., Aguilera, A.R., Green, D., Nicot, B., and Balcom, B.J.
"Direct Hydrocarbon Saturation Imaging in Porous Media with 13C Magnetic Resonance", Petrophysics, accepted.

Ansaribaranghar, N., Zamiri, M.S., Romero-Zerón, L., Marica, F., Aguilera, A.R., Green, D., Nicot, B., and Balcom, B.J.
"Bulk Saturation Measurement of Water and Oil in Porous Media Using 13C and 1H Magnetic Resonance", Petrophysics, accepted.

Zamiri, M.S., Guo, J., and Balcom, B.J.
"T1-T2* Relaxation Correlation Measurements and SPRITE MRI of Shales", Principles of Multidimensional Relaxation and Diffusion Measurements, Eds. Song, Y.Q., Hurlimann, M., Royal Society of Chemistry, New Developments in NMR, accepted.

Published

2024

Morin, D.M., Ansaribaranghar, Nicot, B., Green, D., and Balcom, B.J.
"Selective Enhancement of 1H Signal from Water and Oil in Porous Media at Low Field with Overhauser DNP", Journal of Magnetic Resonance (2024) 368, 107793 (9 pages).pdf
PDF version

Li, M., Kortunov, P., Lee, A., Marica, F., and Balcom, B.J.
"Sandstone Wettability in Supercritical CO2-Brine-Rock Interactions Evaluated with 13C and 1H Magnetic Resonance", Chemical Engineering Journal (2024) 500, 157100 (16 pages).pdfPDF version

Richard, S., Newling, B., and Balcom, B.J.
"A Modular, Low-Field Magnetic Resonance Design with Pre-Polarization for Characterizing Flows", Physics of Fluids (2024) 36, 103629 (12 pages).pdfPDF version

Zamiri, M.S., Afrough, A., Marica, F., Romero-Zerón, L., Nicot, B., and Balcom, B.J.
"Unsteady State Relative Permeability Curves Derived from Saturation Data and Partial Derivatives Using Magnetic Resonance Imaging", Petrophysics (2024) 65(5), 699-710.pdfPDF version

Fricke, S.N., Balcom, B.J., Kaseman, D.C., and Augustine, M.P.
"The Matrix Pencil as a Tunable Filter", Journal of Magnetic Resonance (2024) 368, 107780 (11 pages).pdfPDF version

Ansaribaranghar, N., Zamiri, M.S., Pairoys, F., Fernandes, V., Romero-Zerón, L., Marica, F., Aguilera, A.R., Green, D., Nicot, B., and Balcom, B.J.
"Characterizing Wettability Using 13C Magnetic Resonance Relaxation Times ", International Symposium of the Society of Core Analysts, Fredericton, Canada (2024), 26-29 August (11 pages).pdfPDF version

Zamiri, M.S., Ansaribaranghar, N., Marica, F., Aguilera, A.R., Green, D., Caubit, C., Nicot, B., and Balcom, B.J.
"Relative Permeability Measurement Using Rapid In-Situ Saturation Measurement with 23Na MRI", International Symposium of the Society of Core Analysts, Fredericton, Canada (2024), 26-29 August (10 pages).pdfPDF version

Ansaribaranghar, N., Zamiri, M.S., Romero-Zerón, L., Marica, F., Aguilera, A.R., Dick, M., Green, D., Nicot, B., and Balcom, B.J.
"13C Magnetic Resonance Signal Density and Relaxation Times of Crude Oils", International Symposium of the Society of Core Analysts, Fredericton, Canada (2024), 26-29 August (9 pages).pdfPDF version

Zamiri, M.S., Ansaribaranghar, N., Aguilera, A.R., Marica, F., and Balcom, B.J.
"Fluid Quantification and Kerogen Assessment in Shales Using 13C and 1H Magnetic Resonance", International Symposium of the Society of Core Analysts, Fredericton, Canada (2024), 26-29 August (6 pages).pdfPDF version

Newling, B.
"Short T2 Imaging Applications in Pharmaceutical Research", Magnetic Resonance and its Applications in Drug Formulation and Delivery (2024) Eds. M.D. Mantle and L.P. Hughes, Royal Society of Chemistry, 361-379.pdfPDF version

Rajeev, R., Aguilera, A.R., Marica, F., Romero-Zerón, L., and Balcom, B.J.
"Fast Spin Echo MRI of Reservoir Core Plugs with a Variable Field Magnet", Journal of Magnetic Resonance (2024) 360, 107637 (10 pages).pdfPDF version

Aguilera, A.R., Marica, F., Sanders, K.J., Raihan, M.A., Dyker, C.A., Goward, G.R., and Balcom, B.J.
"Multinuclear MR and MRI Study of Lithium-Ion Cells Using a Variable Field Magnet and a Fixed Frequency RF Probe", Magnetic Resonance Letters (2024) 4, 100090 (11 pages).pdfPDF version

Leger, M.E., Guo, J., MacMillan, B., Titi, H.M., Friscic, T., Balcom, B.J, and Blight, B.A.
"In-Situ Monitoring of Mechanochemical MOF Formation by NMR Relaxation Time Correlation", Physical Chemistry Chemical Physics (2024) 26, 543 (8 pages).pdfPDF version

Morin, D.M., Richard, S., Ansaribaranghar, N., Newling, B., and Balcom, B.J.
"A Low-Field Ceramic Magnet Design for Magnetic Resonance", Journal of Magnetic Resonance (2024) 358, 107599 (9 pages).pdfPDF version

2023

Taylor, J., Richard, S., Balcom, B.J., and Newling, B.
"Spin-Echo Capillary Rheometry Measurements of Foam Flow", Applied Magnetic Resonance (2023) 54, 1543-1553.pdfPDF version

Osmond, D., Selby, W., Romero-Zerón, L., and Mastikhin, I.
"Bulk NMR Measurements of Spray Dynamics", Applied Magnetic Resonance (2023) 54, 1511-1531.pdfPDF version

Aguilera, A.R., Sanders, K.J., Goward, G.R., and Balcom, B.J.
"The Parallel-Plate Resonator: An RF Probe for MR and MRI Studies over a Wide Frequency Range", Magnetic Resonance Letters (2023) 3(4), 306-318.pdfPDF version

Yan, P., Marica, F., Nicot, B.,Green, D., and Balcom, B.J.
"Pore Size Measurement in Core Plugs with Magnetic Resonance Based on Brownstein-Tarr Relaxation Theory", International Symposium of the Society of Core Analysts, Abu Dhabi, UAE (2023), 9-13 October (10 pages).pdfPDF version

Ansaribaranghar, N., Zamiri, M.S., Romero-Zerón, L., Marica, F., Aguilera, A.R., Green, D., Nicot, B., and Balcom, B.J.
"Direct Hydrocarbon Saturation Imaging in Porous Media with 13C", International Symposium of the Society of Core Analysts, Abu Dhabi, UAE (2023), 9-13 October (9 pages).pdfPDF version

Ansaribaranghar, N., Zamiri, M.S., Romero-Zerón, L., Marica, F., Aguilera, A.R., Green, D., Nicot, B., and Balcom, B.J.
"Bulk Saturation Measurement of Water and Oil in Porous Media Using 13C and 1H Magnetic Resonance", International Symposium of the Society of Core Analysts, Abu Dhabi, UAE (2023), 9-13 October (8 pages).pdfPDF version

Richard, S., Balcom, B.J., and Newling, B.
"Determining the Flow Transition from Laminar to Turbulence Using Simple Spin-Echo Magnetic Resonance Techniques", Physics of Fluids (2023) 35(8), 084113 (9 pages).pdfPDF version

Yan, P., Guo, J., Marica, F., and Balcom, B.J.
"Pore Size Distribution Measurement with Magnetic Resonance T2 Distributions Outside the Fast Diffusion Regime", Geoenergy Science and Engineering (2023) 230, 212226 (9 pages).pdfPDF version

Selby, W., Balcom, B.J., Newling, B., and Mastikhin, I.
"Using Phase Interference to Characterize Dynamic Properties-A Review of Constant Gradient, Portable Magnetic Resonance Methods", Frontiers in Physics (2023) 11 (19 pages).pdfPDF version

Yan, P., Marica, F., Guo, J., and Balcom, B.J.
"Direct Measurement of Pore Size and Surface Relaxivity with Magnetic Resonance at Variable Temperature", Physical Review Applied (2023) 20, 014009 (10 pages).pdfPDF version

Zamiri, M.S., Guo, J., Marica, F., Romero-Zerón, L., and Balcom, B.J.
"Shale Characterization Using T1-T2* Magnetic Resonance Relaxation Correlation Measurement at Low and High Magnetic Fields", Petrophysics (2023) 64(3), 384-401 (18 pages).pdfPDF version

Ansaribaranghar, N., Romero-Zerón, L., Marica, F., and Balcom, B.J.
"Measurement of Crude Oil Emulsion Instability Using Magnetic Resonance and Magnetic Resonance Imaging", Colloids and Surfaces A: Physicochemical and Engineering Aspects (2023) 666, 131330 (8 pages).pdfPDF version

2022

Balcom, B.J.
"NMR Relaxometry and Imaging", Chapter 5.14 in "Interaction of Water and Minerals in the Nanometric Pore Space of Clays and Shales: The Claywat Project". Organization for Economic Co-operation and Development (OECD) (2022) .pdfPDF version

Akhtar, N., Ashford, M.B., Beer, L., Bowes, A., Bristow, T., Broo, A., Buttar, D., Coombes, S., Cross, R., Eriksson, E., Guilbaud, J-B., Holman, S.W., Hughes, L.P., Jackman, M., Lawrence, M.J., Lee, J., Li, W., Linke, R., Mahmoudi, N., McCormick, M., MacMillan, B., Newling, B., Ngeny, M., Patterson, C., Poulton, A., Ray, A., Sanderson, N., Sonzini, S., Tang, Y., Treacher, K.E., Whittaker, D., and Wren, S.
"The Global Characterisation of a Drug-Dendrimer Conjugate - PEGylated poly-lysine Dendrimer", Journal of Pharmaceutical Sciences (2022) 112 (3), 844-858 (15 pages).pdfPDF version

Selby, W., Garland, P., and Mastikhin, I.
"A Simple Portable Magnetic Resonance Technique for Characterizing Circular Couette Flow of Non-Newtonian Fluids", Journal of Magnetic Resonance (2022) 345, 107325 (12 pages).pdfPDF version

Zamiri, M.S., Guo, J., Marica, F., Romero-Zerón, L., and Balcom, B.J.
"Shale Characterization Using Magnetic Resonance", International Symposium of the Society of Core Analysts, Austin, Texas, USA (2022), 18-23 September (12 pages).pdfPDF version

Guo, J., Lawrence, M., Adair, A., Newling, B., and Balcom, B.J.
"Laminar Flow Velocity Profile Measurement from Magnetic Resonance Spin Echoes at Incomplete Polarization", Physics of Fluids (2022) 34, 093604 (9 pages).pdfPDF version

Gruber, D.M., Fricke, S.N., Lee, V., Balcom, B.J., and Augustine, M.P.
"Coils for Large Standoff Relaxometry with Unilateral Magnets", Journal of Magnetic Resonance (2022) 342, 107271 (8 pages).pdfPDF version

Guo, J., Zamiri, M.S., and Balcom, B.J.
"Optimization of Two-Dimensional T1*-T2* Relaxation Correlation Measurements in Shale", Journal of Petroleum Science and Engineering (2022) 217, 110939 (10 pages).pdfPDF version

Morin, D.M., Lawrence, M., and Balcom, B.J.
"Design and Validation of a Single-Sided Magnet with a Constant Gradient Parallel to its Surface", Journal of Magnetic Resonance (2022) 342, 107266 (7 pages).pdfPDF version

Gauthier, A.P., Stocek, N., and Newling, B.
"Diffusion Tensor Imaging of Anisotropic Inhomogeneous Turbulent Flow", Physical Review E (2022) 106, 015108 (9 pages).pdfPDF version

Zamiri, M.S., Guo, J., Marica, F., Romero-Zerón, L., and Balcom, B.J.
"Characterization of Kerogen in Shale Core Plugs Using T2*-Based Magnetic Resonance Methods", Fuel (2022) 324, 124573 (8 pages).pdfPDF version

Selby, W., Garland, P., and Mastikhin, I.
"Dynamic Mechanical Analysis with Portable NMR", Journal of Magnetic Resonance (2022) 339, 107211 (9 pages).pdfPDF version

Zhang, M., and Balcom, B.J.
"Magnetic Resonance Studies of Water in Wood Materials", Magnetic Resonance Microscopy. Instrumentation and Applications in Engineering, Life Science and Energy Research, Eds. Haber-Pohlmeier, S., Bluemich, B., and Ciobanu, L., John Wiley & Sons (2022) .pdfPDF version

Gill, M., and Newling, B.
"The Determination of Sucrose Content in Maple Sap Using Time-Domain Magnetic Resonance", Sugar Tech (2022) 24, 882-889 (8 pages).pdfPDF version

Sanders, K.J., Aguilera, A.R., Keffer, J.R., Balcom, B.J., Halalay, I.C., and Goward, G.R.
"Transient Lithium Metal Plating on Graphite: Operando 7Li Nuclear Magnetic Resonance Investigation of a Battery Cell Using a Novel RF Probe", Carbon (2022) 189, 377-385 (9 pages).pdfPDF version

Morin, D.M., Yan, P., Augustine, M.P., and Balcom, B.J.
"An Optimized 2 MHz Unilateral Magnet with a Large Homogeneous Sensitive Spot", Applied Magnetic Resonance (2022) 53, 401-415 (15 pages).pdfPDF version

Guo, J., Zamiri, M.S., and Balcom, B.J.
"Rapid Measurement of T1*-T2* Relaxation Correlation with a Look-Locker Sequence", Journal of Magnetic Resonance (2022) 335, 107123 (8 pages).pdfPDF version

Ahmadi, S., Aguilera, A.R., MacMillan, B., and Mastikhin, I.
"Studies of Periodic Seawater Spray Icing with Unilateral NMR", Journal of Magnetic Resonance (2022) 334, 107109 (10 pages).pdfPDF version

Zamiri, M.S., Marica, F., Romero-Zerón, L., and Balcom, B.J.
"Monitoring Shale Water Uptake Using 2D Magnetic Resonance Relaxation Correlation and SPRITE MRI", Chemical Engineering Journal (2022) 428, 131042 (12 pages).pdfPDF version

2021

Guo, J., Ross, M.M.B, Newling, B., Lawrence, M., and Balcom, B.J.
"Laminar Flow Characterization Using Low-Field Magnetic Resonance Techniques", Physics of Fluids (2021) 33, 103609 (14 pages).pdfPDF version

Afrough, A., Marica, F., MacMillan, B., and Balcom, B.J.
"Pore-Size Measurement from Eigenvalues of Magnetic Resonance Relaxation", Physical Review Applied (2021) 16, 034040 (16 pages).pdfPDF version

Safari, H., Balcom, B.J. and Afrough, A.
"Characterization of Pore and Grain Size Distributions in Porous Geological Samples - An Image Processing Workflow", Computers and Geosciences (2021) 156, 104895 (14 pages).pdfPDF version

Guo, J., Ross, M.M.B., Newling, B., and Balcom, B.J.
"Non-Newtonian Fluid Velocity Profiles Determined with Simple Magnetic Resonance Spin Echoes", Physical Review Applied (2021) 16, L021001 (6 pages).pdfPDF version

Guo, J., MacMillan, B., Zamiri, M.S., and Balcom, B.J.
"Two Dimensional 1H Magnetic Resonance Relaxometry-Based Analyses of Argonne Premium Coals", Fuel (2021) 302, 121106 (9 pages).pdfPDF version

Guo, J., MacMillan, B., Zamiri, M.S., and Balcom, B.J
"Magnetic Resonance T1-T2* and T-T2* Relaxation Correlation Measurements in Solid-Like Materials with Non-Exponential Decays", Journal of Magnetic Resonance (2021) 328, 107005 (15 pages).pdfPDF version

Ross, M.M.B., Wilbur, G.R., Cano Barrita, P., and Balcom, B.J.
"A Portable, Submersible, MR Sensor - The Proteus Magnet", Journal of Magnetic Resonance (2021) 326, 106964 (8 pages).pdfPDF version

Enjilela, R., Guo, J., MacMillan, B., Marica, F., Afrough, A., and Balcom, B.J.
"T1-T2* Relaxation Correlation Measurements", Journal of Magnetic Resonance (2021) 326, 106961 (8 pages).pdfPDF version

Aguilera, A.R., MacMillan, B., Krachkovskiy, S., Sanders, K.J., Alkhayri, F., Dyker, C.A., Goward, G.R., and Balcom, B.J.
"A Parallel-Plate RF Probe and Battery Cartridge For 7Li Ion Battery Studies", Journal of Magnetic Resonance (2021) 325, 106943 (8 pages).pdfPDF version

Adair, A., Richard, S., and Newling, B.
"Gas and Liquid Phase Imaging of Foam Flow Using Pure Phase Encode Magnetic Resonance Imaging", Molecules (2021) 26(1), 28 (9 pages).pdfPDF version

Zamiri, M.S., MacMillan, B., Marica, F., Guo, J., Romero-Zerón, L., Balcom, B.J.
"Petrophysical and Geochemical Evaluation of Shales Using Magnetic Resonance T1-T2* Relaxation Correlation", Fuel (2021) 284, 119014 (11 pages).pdfPDF version

2020

Krachkovskiy, S.A., Reza, M., Aguilera, A.R., Halalay, I.C, Balcom, B.J., and Goward, G.R.
"Real-Time Quantitative Detection of Lithium Plating by In Situ NMR Using a Parallel-Plate Resonator", Journal of The Electrochemical Society (2020) 167, 130514 (6 pages).pdfPDF version

Adair, A., Balcom, B.J., Newling, B.
"Velocity Mapping of Fast Flows Using a Linearly Ramped Gradient Waveform", Journal of Magnetic Resonance (2020) 316, 106754 (7 pages).pdfPDF version

Ahmadi, S., Mastikhin, I.
"Velocity Measurement of Fast Flows Inside Small Structures with Tagged MRI", Applied Magnetic Resonance (2020) 51, (18 pages).pdfPDF version

Shakerian, M., Afrough, A., Vashaee, S., Marica, F., Zhao, Y., Zhao, J., Song, Y., Balcom, B.J.
"Direct Measurement of Pore Gas Pressure and Water/Gas Phase Transitions during Methane Hydrate Dissociation", Marine and Petroleum Geology (2020) 116, 104296 (9 pages).pdfPDF version

Wilbur, G., MacMillan, B., Bade, K.M., Mastikhin, I.
"MRI monitoring of sea spray freezing", Journal of Magnetic Resonance (2020) 310, 106647 (9 pages).pdfPDF version

2019

Hopkins, E.J., Newling, B., Hucl, P., Scanlon, M.G., Nickerson, M.T.
"Water mobility and association by 1H NMR and diffusion experiments in simple model bread dough systems containing organic acids", Food Hydrocolloids (2019) 95, 283-291 (9 pages).pdfPDF version

Martin, M.N., Balcom, B.J., McCarthy, M.J., Augustine, M.P.
"Noninvasive, Nondestructive Measurement of Tomato Concentrate Spoilage in Large Volume Aseptic Packages", Journal of Food Science (2019) 84, 2898-2906 (9 pages).pdfPDF version

Enjilela, R., MacMillan, B., McAloon, M.J., Petrov, O.V., Vashaee, S., Balcom, B.J.
"Controlling susceptibility mismatch effects, signal lifetimes, and SNR through variation of B0 in MRI of rock core plugs", Journal of Magnetic Resonance (2019) 307, 106575 (9 pages).pdfPDF version

Marica, F., Afrough, A., Green, D., Romero-Zerón, L., Balcom, B.J.
"Direct Magnetic Resonance Measurement of Average Pore Size", International Symposium of the Society of Core Analysts, Pau, France (2019), 26-29 August (7 pages).pdfPDF version

Kerr, J.D., Balcom B.J., McCarthy, M.J., Augustine M.P.
"A Low Cost, Portable NMR Probe for High Pressure, MR Relaxometry", Journal of Magnetic Resonance (2019) 304, 35-41 (7 pages).pdfPDF version

Richard, S., Newling, B.
"Measuring Flow Using a Permanent Magnet with a Large Constant Gradient", Applied Magnetic Resonance (2019) 50, 627-635 (9 pages).pdfPDF version

Afrough, A., Vashaee, S., Romero-Zerón, L., Balcom, B.J.
"Absolute Measurement of Pore Size based on Nonground Eigenstates in Magnetic-Resonance Relaxation", Physical Review Applied (2019) 11, 041002 (6 pages).pdfPDF version

Newling, B., Adair, A.J., Goora, F.G.
"Magnetic Field Gradient Waveform Correction of Motion-Sensitized SPRITE", Journal of Magnetic Resonance (2019) 298, 58-63 (6 pages).pdfPDF version

Xiao, D., and Balcom, B.J.
"Ultra-short Echo Time Imaging with Multiple Echo Refocusing for Porous Media T2 Mapping", Journal of Magnetic Resonance (2019) 299, 33-41 (9 pages).pdfPDF version

2018

Gauthier, A.R., Newling, B.
"Magnetic Resonance Imaging of Fast Turbulent Gas Flow", Physics in Canada (2018) 74, 119-122 (4 pages).pdfPDF version

Aguilera, A.R., MacMillan, B., Goward, G.R., Balcom, B.J.
"Optimization of a Parallel-Plate RF Probe for High Resolution Thin Film Imaging", Concepts in Magnetic Resonance Part A (2018) e21465 (9 pages).pdfPDF version

Gauthier, A.P., Newling, B.
"Gas Flow Mapping in a Recorder: An Application of SPRITE MRI", Applied Magnetic Resonance (2018) 49, 1151-1162 (14 pages).pdfPDF version

Krachkovskiy, S.A., Foster, J.M., Bazak, J.D., Balcom, B.J., Goward, G.R.
"Operando Mapping of Li Concentration Profiles and Phase Transformations in Graphite Electrodes by Magnetic Resonance Imaging and Nuclear Magnetic Resonance Spectroscopy", Journal of Physical Chemistry C (2018) 122, 21784-21791.pdfPDF version

Afrough, A., Moghaddam, M.B., Romero-Zerón, L., Balcom, B.J.
"Exponential Capillary Pressure Functions in Sedimentary Rocks", International Symposium of the Society of Core Analysts, Trondheim, Norway (2018), 27-30 August (9 pages).pdfPDF version

Shakerian, M., Afrough, A., Vashaee, S., Marica, F., Zhao, Y., Zhao, J., Song, Y., Balcom, B.J.
"Monitoring Gas Hydrate Formation with Magnetic Resonance Imaging in a Metallic Core Holder", International Symposium of the Society of Core Analysts, Trondheim, Norway (2018), 27-30 August (13 pages).pdfPDF version

Adair, A., Mastikhin, I.V., Newling, B.
"Motion-Sensitized SPRITE Measurements of Hydrodynamic Cavitation in Fast Pipe Flow", Magnetic Resonance Imaging (2018) 49, 71-77 (7 pages).pdfPDF version

Afrough, A., Shakerian, M., Zamiri, M.S., MacMillan, B., Marica, F., Newling, B., Romero-Zerón, L., Balcom, B.J.
"Magnetic Resonance Imaging of High Pressure Carbon Dioxide Displacement: Fluid/Surface Interaction and Fluid Behavior", SPE Journal (2018) 189458 (16 pages).pdfPDF version

Merz, S., Balcom, B.J., Enjilela, R., Vanderborght, J., Rothfuss, Y., Vereecken H., and Pohlmeier, A.
"Magnetic Resonance Monitoring and Numerical Modeling of Soil Moisture during Evaporation", Vadose Zone Journal (2018) 17, 160099 (15 pages).pdfPDF version

Enjilela, R., Cano-Barrita, P.F de J., Komar, A., Boyd, A.J., Balcom, B.J.
"Wet Front Penetration with Unsteady State Wicking in Mortar Studied by Magnetic Resonance Imaging (MRI)", Materials and Structures (2018) 51, 16 (16 pages).pdfPDF version

Vashaee, S., Li, M., Newling, B., MacMillan, B., Marica, F., Kwak, H.T., Gao, J., Al-harbi, A.M. and Balcom, B.J.
"Local T1-T2 Distribution Measurements in Porous Media", Journal of Magnetic Resonance (2018) 287, 113-122 (10 pages).pdfPDF version

Shakerian, M., and Balcom, B.J.
"An MR/MRI Compatible Core Holder with the RF Probe Immersed in the Confining Fluid", Journal of Magnetic Resonance (2018) 286, 36-41 (6 pages).pdfPDF version

2017

Shakerian, M., Marica, F., Afrough, A., Goora, F., Ming, L., Vashaee, S., and Balcom, B.J.
"A High-Pressure Metallic Core Holder for Magnetic Resonance Based on Hastelloy-C", Review of Scientific Instruments (2017) 88, 123703 (8 pages).pdfPDF version

Afrough, A., Zamiri, M.S., Romero-Zerón, L., and Balcom, B.J.
"Magnetic Resonance Imaging of Fines Migration in Berea Sandstone", SPE Journal (2017) 22, 1385-1392.pdfPDF version

Ming, L., Vashaee, S., Romero-Zerón, L., Marica, F., and Balcom, B.J.
"A Magnetic Resonance Study of Low Salinity Waterflooding for Enhanced Oil Recovery", Energy & Fuels (2017) 31, 10802-10811.pdfPDF version

Xiao, D., and Balcom, B.J.
"BLIPPED (BLIpped Pure Phase EncoDing) High Resolution MRI with Low Amplitude Gradients", Journal of Magnetic Resonance (2017) 285, 61-67.pdfPDF version

Mastikhin, I., Bade, K., and Ahmadi, S.
"A rapid magnetization preparation for MRI measurements of sprays", Journal of Magnetic Resonance (2017) 283, 52-60.pdfPDF version

Vashaee, S., Li, M., MacMillan, B., Enjilela, R., Green, D., Marcia, F., and Balcom, B.J.
"Magnetic Resonance Imaging with a Variable Field Superconducting Magnet that can be Rotated for Vertical or Horizontal Operation", International Symposium of the Society of Core Analysts, Vienna, Austria (2017), 28-31 August, 12 pages.pdfPDF version

Lamason, C., MacMillan, B., Balcom, B.J., Leblon, B., and Pirouz, Z.
"Magnetic resonance studies of wood log-drying processes", Forest Products Journal (2017) 67(3/4), 266-274.pdfPDF version

Li, M., Romero-Zerón, L., Marica, F., and Balcom, B.J.
"Polymer Flooding Enhanced Oil Recovery Evaluated with Magnetic Resonance Imaging and Relaxation Time Measurements", Energy & Fuels (2017) 31, 4904-4915.pdfPDF version

Lamason, C., MacMillan, B., Balcom, B.J., Leblon, B., and Pirouz, Z.
"Field Measurements of Moisture Content in Black Spruce Logs with Unilateral Magnetic Resonance", Forest Products Journal (2017) 67, 55-62.pdfPDF version

Vashaee, S., Newling, B., MacMillan, B., Marica, F., Li, M., and Balcom, B.J.
"Local Diffusion and Diffusion-T2 Distribution Measurements in Porous Media", Journal of Magnetic Resonance (2017) 278, 104-112.pdfPDF version

Enjilela, R., Cano-Barrita, P.F de J., Komar, A., Boyd, A., and Balcom, B. J.
"Monitoring Steady State Moisture Distribution during Wick Action in Mortar by Magnetic Resonance Imaging (MRI)", Materials and Structures (2017) 50:151 (12 pages).pdfPDF version

Cano-Barrita, P.F de J., Balcom, B.J.,and Castellanos, F.
"Carbonation front in cement paste detected by T2 NMR measurements using a low field unilateral magnet", Materials and Structures (2017) 50:150 (8 pages).pdfPDF version

Xiao, D., and Balcom, B.J.
"T2 Selective π Echo-Planar Imaging for Porous Media MRI", Journal of Magnetic Resonance (2017) 277, 52-58.pdfPDF version

Acevedo, N.C., MacMillan, B., Newling, B., and Marangoni, A.G.
"Shear Effects on the Diffusive Movement of Oil in Triacylglycerol Networks", RSC Advances (2017) 7, 1634-1642.pdfPDF version

2016

McDonald, T., MacMillan, B., Newling, B., Balcom, B.
"Systematic Image Alteration due to Phase Accumulation during RF Pulse Excitation in Pure Phase Encode Magnetic Resonance Imaging", Concepts in Magnetic Resonance Part A (2016) 45A:e21425 (8 pages).pdfPDF version

Li, M., Xiao, D., Shakerian, M., Afrough, A., Goora, F., Marica, F., Romero-Zerón, L., and Balcom, B.J.
"Magnetic Resonance Imaging of Core Flooding in a Metal Core Holder", International Symposium of the Society of Core Analysts, Snowmass, Colorado, USA (2016), 21-26 August, 12 pages.pdfPDF version

Goora, F.G., and Balcom, B.J.
"Accuracy of the Magnetic Field Gradient Waveform Monitor (MFGM) Technique and Consequent Accuracy of Pre-Equalized Gradient Waveforms", Concepts in Magnetic Resonance Part B (Magnetic Resonance Engineering) (2016) 46B(2), 67-80.pdfPDF version

Krachkovskiy, S.A., Bazak, J.D., Werhun, P., Balcom, B.J., Halalay, I.C., and Goward, G.R.
"Visualization of Steady-State Ionic Concentration Profiles Formed in Electrolytes During Li-Ion Battery Operation and Determination of Mass Transport Properties by In-Situ Magnetic Resonance Imaging", Journal of the American Chemical Society (2016) 138, 7992-7999.pdfPDF version

Li, M., Xiao, D., Romero-Zerón, L., Marica, F., MacMillan, B. and Balcom, B. J.
"Mapping Three-Dimensional Oil Distribution with π-EPI MRI Measurements at Low Magnetic Field", Journal of Magnetic Resonance (2016) 269, 13-23.pdfPDF version

Mastikhin, I., Arbabi, A., and Bade, K.M.
"Magnetic Resonance Imaging Measurements of a Water Spray Upstream and Downstream of a Spray Nozzle Exit Orifice", Journal of Magnetic Resonance (2016) 266, 8-15.pdfPDF version

Li, M., Xiao, D., Romero-Zerón, L., and Balcom, B.J.
"Monitoring Oil Displacement Processes with k-t Accelerated Spin Echo SPI", Magnetic Resonance in Chemistry (2016) 54, 197-204.pdfPDF version

Merz, S., Pohlmeier, A., Balcom, B.J., Enjilela, R., and Vereecken, H.
"Drying of a Natural Soil Under Evaporative Conditions: A Comparison of Different Magnetic Resonance Methods", Applied Magnetic Resonance (2016) 47, 121-138.pdfPDF version

Ouellette, M., Li, M., Liao, G., Hussein, E.M.A., Romero-Zerón, L., and Balcom, B.J.
"Rock Core Analysis: Metallic Core Holders for Magnetic Resonance Imaging Under Reservoir Conditions", Mobile NMR and MRI - Developments and Applications', Ed. Johns, M., Royal Society of Chemistry, New Developments in NMR (2016) pp. 290-309.pdfPDF version

2015

Vashaee, S., Newling, B., and Balcom, B.J.
"Local T2 Measurement Employing Longitudinal Hadamard Encoding and Adiabatic Inversion Pulses in Porous Media", Journal of Magnetic Resonance (2015) 261, 141-148.pdfPDF version

Xiao, D., and Balcom, B.J.
"π Echo-Planar Imaging with Concomitant Field Compensation for Porous Media MRI", Journal of Magnetic Resonance (2015) 260, 38-45.pdfPDF version

Vashaee, S. , Marica, F., Newling, B., and Balcom, B.J.
"A Comparison of Magnetic Resonance Methods for Spatially Resolved T2 Distribution Measurements in Porous Media", Measurement Science and Technology (2015) 26, 055601 (16pp).pdfPDF version

Lamason, C., MacMillan, B., Balcom, B.J., Leblon, B., and Pirouz, Z.
"Water content measurement in black spruce and aspen sapwood with benchtop and portable magnetic resonance devices", Wood Material Science and Engineering (2015) 10, 86-93.pdfPDF version

Vashaee, S., Goora, F., Britton, M.M., Newling, B., and Balcom, B.J.
"Mapping B1-induced eddy current effects near metallic structures in MR images: a comparison of simulation and experiment", Journal of Magnetic Resonance (2015) 250, 17-24.pdfPDF version

2014

Arbabi, A., Hall, J., Richard, P., Wilkins, S., Mastikhin, I.V.
"MR relaxometry of micro-bubbles in the vertical bubbly flow at a low magnetic field (0.2 T) ", Journal of Magnetic Resonance (2014) 249, 16-23.pdfPDF version

Mastikhin, I., Barnhill, M.
"Sensitization of a stray-field NMR to vibrations: A potential for MR elastometry with a portable NMR sensor", Journal of Magnetic Resonance (2014) 248, 1-7.pdfPDF version

Garcia-Naranjo, J.C., Guo, P., Marica, F., Liao, G., and Balcom, B.J.
"Magnetic Resonance Core Plug Analysis with the Three-Magnet Array Unilateral Magnet", Petrophysics (2014) 55(3), 229-239.pdfPDF version

Lamason, C., MacMillan, B., Balcom, B.J., Leblon, B., and Pirouz, Z.,
"Examination of Water Phase Transitions in Black Spruce by Magnetic Resonance and Magnetic Resonance Imaging", Wood and Fiber Science (2014) 46, 1-14.pdfPDF version

Xiao, D., and Balcom, B.J.
"k-t Acceleration in Pure Phase Encode MRI to Monitor Dynamic Flooding Processes in Rock Core Plugs", Journal of Magnetic Resonance (2014) 243, 114-121.pdfPDF version

Muir, C.E., Petrov, O.V., Romanenko, K.V., and Balcom, B.J.
"Measuring miscible fluid displacement in porous media with magnetic resonance imaging", Water Resources Research (2014) 50, 1859-1868.pdfPDF version

Marica, F., Goora, F.G. and Balcom, B.J.
"FID-SPI Pulse Sequence for Quantitative MRI of Fluids in Porous Media", Journal of Magnetic Resonance (2014) 240, 61-66.pdfPDF version

Vashaee, S., Petrov, O.V., Balcom, B.J., and Newling, B.
"Region of Interest Selection of Long Core Plug Samples by Magnetic Resonance Imaging: Profiling and Local T2 measurement", Measurement Science and Technology (2014) 25, 035004 (10pp).pdfPDF version

Nechifor, R.E., Romanenko, K., Marica, F., and Balcom, B.J.
"Spatially Resolved Measurements of Mean Spin-Spin Relaxation Time Constants", Journal of Magnetic Resonance (2014) 239, 16-22.pdfPDF version

Goora, F.G., Colpitts, B.G., and Balcom, B.J.
"Arbitrary Magnetic Field Gradient Waveform Correction Using an Impulse Response Based Pre-Equalization Technique", Journal of Magnetic Resonance (2014) 238, 70-76.pdfPDF version

2013

Romanenko, K. and Balcom, B.J.
"An Assessment of Non-wetting Phase Relative Permeability in Water-wet Sandstones Based on Quantitative MRI of Capillary End Effects", Journal of Petroleum Science and Engineering (2013) 110, 225-231.pdfPDF version

Adegbite, O., Kadem, L. and Newling, B.
"Purely phase-encoded MRI of turbulent flow through a dysfunctional bileaflet mechanical heart valve", Magnetic Resonance Materials in Physics, Biology and Medicine (MAGMA) (2013) 41648, 10334-013-0408-1.pdfPDF version

Diaz-Diaz, F., Cano-Barrita, P.F de J., Balcom, B.J., Solis-Najera, S.E., and Rodriguez, A.O.
"Embedded NMR sensor to monitor compressive strength development and pore size distribution in hydrating low and high water-to-cement ratio concrete", Sensors (2013) 13, 15986-15999.pdfPDF version

Xiao, D. and Balcom, B.J.
"Hybrid-SPRITE MRI", Journal of Magnetic Resonance (2013) 235, 6-14.pdfPDF version

Ouellette, M., Han, H., MacMillan, B., Goora, F., MacGregor, R., Hassan, M. and Balcom, B.J.
"Design of a Magnetic Resonance Imaging Compatible Metallic Pressure Vessel", Journal of Pressure Vessel Technology (2013) 135, 045001-1 - 045001-7.pdfPDF version

Mastikhin, I.V. and Arbabi, A.
"Transiently Porous Medium: Magnetic Resonance Imaging Studies of Acoustic Cavitation", Microporous and Mesoporous Materials (2013) 178, 41704.pdfPDF version

Vashaee, S., Newling, B., MacMillan, B. and Balcom, B.J.
"B1 Mapping with a Pure Phase Encode Approach: Quantitative Density Profiling", Journal of Magnetic Resonance (2013) 232, 68-75.pdfPDF version

Goora, F.G., Han, H., Ouellette, M., Colpitts, B.G. and Balcom, B.J.
"Investigation of Magnetic Field Gradient Waveforms in the Presence of a Metallic Vessel in Magnetic Resonance Imaging Through Simulation", IEEE Transactions on Magnetics (2013) 49(6), 2920-2932.pdfPDF version

Muir, C.E. and Balcom, B.J.
"A Comparison of Magnetic Resonance Imaging Methods for Fluid Content Imaging in Porous Media", Magnetic Resonance in Chemistry (2013) 51, 321-327.pdfPDF version

Xiao, D. and Balcom, B.J.
"Restricted k-space Sampling in Pure Phase Encode MRI of Rock Core Plugs", Journal of Magnetic Resonance (2013) 231, 126-132.pdfPDF version

Kaffanke, J.B., Romanzetti, S., Dierkes, T., Leach, M.O., Balcom, B.J. and Shah, N.J.
"Multi-Frame SPRITE: A Method for Resolution Enhancement of Multiple-Point SPRITE Data", Journal of Magnetic Resonance (2013) 230, 111-116.pdfPDF version

2012

Romanenko, K. and Balcom, B.J.
"Permeability Mapping in Naturally Heterogeneous Sandstone Cores by Magnetization Prepared Centric-Scan SPRITE", AIChE Journal (2012) 58, 3916-3926.pdfPDF version

Arbabi, A., Mastikhin, I.V.
"Magnetic Susceptibility Based Magnetic Resonance Estimation of Micro-bubble Size for the Vertically Upward Bubbly Flow", Journal of Magnetic Resonance (2012) 225, 36-45.pdfPDF version

Kwak, H.T., Al-Nakhli, A.R., Abass, H.H., Funk, J.J., Saudi, A. and Balcom, B.J.
"New Insights into Microscopic Fluid/Rock Interaction: MR-CT Microscopy Approach", SPE Annual Technical Conference and Exhibition, San Antonio, Texas, USA, 2012, 8-10 October.pdfPDF version

Muir, C.E. and Balcom, B.J.
"Pure Phase Encode Magnetic Resonance Imaging of Fluids in Porous Media", Annual Reports on NMR Spectroscopy, Vol. 77 (2012 ) Burlington: Academic Press, 81-113.pdfPDF version

Romanenko, K., Xiao, D. and Balcom, B.J.
"Velocity field measurements in sedimentary rock cores by magnetization prepared 3D SPRITE", Journal of Magnetic Resonance (2012) 223, 120-128.pdfPDF version

Goora, F.G., Han, H., Colpitts, B.G. and Balcom, B.J.
"Simulation and Verification of Magnetic Field Gradient Waveforms in the Presence of a Metallic Vessel in Magnetic Resonance Imaging", IEEE Transactions on Magnetics (2012) 48, 2440-2448.pdfPDF version

Green, D., Veselinovic, D., Balcom, B.J., and Marica, F.
"Applications of a new technique to acquire spatially resolved NMR petrophysical data", International Symposium of the Society of Core Analysts, Aberdeen, Scotland, UK, (2012), 27-30 August, 12 pages.pdfPDF version

Mastikhin, I.V. and Balcom, B.J.
"'Centric SPRITE MRI of Biomaterials with Short T2*' in MRI of Tissues with Short T2s or T2*s", (2012 ), Bydder, G.M., Fullerton, G.D. and Young, I.R. (eds). (Encyclopedia of Magnetic Resonance) John Wiley & Sons Ltd, Chichester, UK, pp 61-67.pdfPDF version

Xiao, D. and Balcom, B.J.
"Two-Dimensional T2 Distribution Mapping in Rock Core Plugs with Optimal k-Space Sampling", Journal of Magnetic Resonance (2012) 220, 70-78.pdfPDF version

Prado, P.J., Mastikhin, I.V. and Karlsson, M.T.
"Rapid Method to Screen Unopened Bottles to Detect Concealed Drugs", Applied Magnetic Resonance (2012) 43, 531-540.pdfPDF version

Petrov, O.V. and Balcom, B.J.
"Local T2 Distribution Measurements with DANTE-Z Slice Selection", Journal of Magnetic Resonance (2012) 215, 109-114.pdfPDF version

Mastikhin, I.V., Hetherington, N.L. and Emms, R.
"Oscillating Gradient Measurements of Fast Oscillatory and Rotational Motion in the Fluids", Journal of Magnetic Resonance (2012) 214, 189-199.pdfPDF version

Mastikhin, I.V., Arbabi, A., Newling, B., Hamza, A. and Adair, A.
"Magnetic Resonance Imaging of Velocity Fields, the Void Fraction and Gas Dynamics in a Cavitating Liquid", Experiments in Fluids (2012) 52, 95-104.pdfPDF version

2011

Newling, B., Poirier, C.P., Snow, T.A., Glover, P.M., Colpitts, B.G., Mastikhin, I.V., Hetherington, N.L., MacGregor, R.P. and Balcom, B.J.
"A Fast-Switching, Low-Inductance Gradient Set for Motion Encoding", Concepts in Magnetic Resonance B: Magnetic Resonance Engineering (2011) 39B4, 173-17.pdfPDF version

MacMillan, B., Veliyulin, E., Lamason, C. and Balcom, B.J.
"Quantitative Magnetic Resonance Measurements of Low Moisture Content Wood", Canadian Journal of Forest Research (2011) 41, 2158-2162.pdfPDF version

Han, H., Ouellette, M., MacMillan, B., Goora, F., MacGregor, R., Green, D. and Balcom, B.J.
"High Pressure Magnetic Resonance Imaging with Metallic Vessels", Journal of Magnetic Resonance (2011) 213, 90-97.pdfPDF version

Marica, F., Jofré, S.A.B., Mayer, K.U., Balcom, B.J. and Al, T.A.
"Determination of Spatially-Resolved Porosity, Tracer Distributions and Diffusion Coefficients in Porous Media Using MRI Measurements and Numerical Simulations", Journal of Contaminant Hydrology (2011) 125, 47-56.pdfPDF version

Han, H. and Balcom, B.J.
"Magnetic Resonance Imaging inside Cylindrical Metal Containers with an Eddy Current Self-compensated Method", Measurement Science and Technology (2011) 22, 115501 (7pp).pdfPDF version

Zhang, Z. and Balcom, B.J.
"Magnetic Resonance Imaging", in 'PEM Fuel Cell Diagnostic Tools', Eds. Wang, H., Yuan, X. and Li, H., Taylor and Francis, Oxford, UK (2011 ) 229-254.pdfPDF version

Petrov, O.V. and Balcom, B.J.
"Two-Dimensional T2 Distribution Mapping in Porous Solids with Phase Encode MRI", Journal of Magnetic Resonance (2011) 212, 102-108.pdfPDF version

Zhang, Z., Marble, A.E., MacGregor, R.P., Martin, J., Wang, H. and Balcom, B.J.
"Zero-mode TEM Parallel-plate Resonator for High-resolution Thin Film Magnetic Resonance Imaging", Can. J. Chem. (2011) 89, 745-753.pdfPDF version

Zhang, Z., Promislow, K., Martin, J., Wang, H. and Balcom, B.J.
"Bi-modal Water Transport Behavior across a Simple Nafion Membrane", Journal of Power Sources (2011) 196, 8525-8530.pdfPDF version

LaPlante, G., Garcia-Naranjo, J.C. and Balcom, B.J.
"Real-time Cure Monitoring of an Epoxy/Polyamidoamine System with Unilateral Magnetic Resonance", NDT&E International (2011) 44, 329-334.pdfPDF version

Petrov, O., Ersland, G. and Balcom, B.J.
"T2 Distribution Mapping Profiles with Phase Encode MRI", Journal of Magnetic Resonance (2011) 209, 39-46.pdfPDF version

Muir, C.E., Lowry, B.J., and Balcom, B.J.
"Measuring Diffusion using the Differential form of Fick's Law and Magnetic Resonance Imaging", New Journal of Physics (2011) 13, 015005 (15pp).pdfPDF version

Romanenko, K. and Balcom, B.J.
"Permeability Mapping in Porous Media by Magnetization Prepared Centric-Scan SPRITE", Experiments in Fluids (2011) 50, 301-312.pdfPDF version

2010

Mastikhin, I.V., Teslenko, V.S., Nikolin, V.P., Kolosova, N.G. and Gorchakov, V.N.
"Tumor Growth Inhibition by Combined Action of Shock Waves and Cytostatics", New Trends in Shock Wave Applications to Medicine and Biotechnology (2010) 151-164.pdfPDF version

Garcia-Naranjo, J.C., Mastikhin, I.V., Colpitts, B.G. and Balcom, B.J.
"A Unilateral Magnet with an Extended Constant Magnetic Field Gradient", Journal of Magnetic Resonance (2010) 207, 337-344.pdfPDF version

Han, H., Ouriadov, A., Fordham, E. and Balcom, B.J.
"Direct Measurement of Magnetic Field Gradient Waveforms", Concepts in Magnetic Resonance Part A (2010) 36B(6), 349-360.pdfPDF version

Han, H., Green, D., Ouellette, M., MacGregor, R. and Balcom, B.J.
"Non-Cartesian Sampled Centric Scan SPRITE Imaging with Magnetic Field Gradient and B0(t) Field Measurements for MRI in the Vicinity of Metal Structures", Journal of Magnetic Resonance (2010) 206, 97-104.pdfPDF version

Tayler, A.B., Sederman, A.J., Newling, B., Mantle, M.D., and Gladden, L.F.
"'Snap-shot' velocity vector mapping using echo-planar imaging", Journal of Magnetic Resonance (2010) 204, 266-272.pdfPDF version

Han, H. and Balcom, B.J.
"Magnetic Resonance Imaging Measurements Inside Metallic Vessels", Measurement Science and Technology (2010) 21, 103001.pdfPDF version

Zhang, J. and Balcom, B.J.
"Parallel-Plate RF Resonator Imaging of Chemical Shift Resolved Capillary Flow", Magnetic Resonance Imaging (2010) 28, 826-833.pdfPDF version

Zhang, J. and Balcom, B.J.
"Magnetic Resonance Imaging of Two-Component Liquid-Liquid Flow in a Circular Capillary Tube", Physical Review E (2010) 81, 56318.pdfPDF version

Romero-Zerón, L., Ongsurakul, S., Li, L. and Balcom, B.J.
"Magnetic Resonance Imaging of Phase Trapping and In-situ Permeability Modification in Unconsolidated Porous Media", Petroleum Science and Technology (2010) 28, 262-276.pdfPDF version

Romero-Zerón, L., Ongsurakul, S., Li, L. and Balcom, B.J.
"Visualization of the Effect of Porous Media Wettability on Polymer Flooding Performance through Unconsolidated Porous Media using Magnetic Resonance Imaging", Petroleum Science and Technology (2010) 28, 52-67.pdfPDF version

Garcia-Naranjo, J.C., Glover, P.M., Marica, F. and Balcom, B.J.
"Variable Bandwidth Filtering for Magnetic Resonance Imaging with Pure Phase Encoding", Journal of Magnetic Resonance (2010) 202, 234-238.pdfPDF version

2009

Vargas-Vasquez, S.M., Romero-Zerón, L.B. and MacMillan, B.
"Characterization of Cr(II) and Cr(III) acetate aqueous solutions using UV-vis spectrophotometry and 1H NMR", Chemical Engineering Communications (2009) 197, 491-505.pdfPDF version

Han, H., MacGregor, R.P. and Balcom, B.J.
"Pure Phase Encode Magnetic Field Gradient Monitor", Journal of Magnetic Resonance (2009) 201, 212-217.pdfPDF version

Romero-Zerón, L., Ongsurakul, S., Li, L. and Balcom, B.J.
"Visualization of Waterflooding through Unconsolidated Porous Media using Magnetic Resonance Imaging", Petroleum Science and Technology (2009) 27, 1532-2459.pdfPDF version

Romero-Zerón, L., Ongsurakul, S., Li, L. and Balcom, B.J.
"Visualization of Mobility-Control by Polymer Waterflooding through Unconsolidated Porous Media using Magnetic Resonance Imaging", Petroleum Science and Technology (2009) 27, 2046-2062.pdfPDF version

Setthanan, U., MacMillan, B., McGrady, S.
"Spatially resolved hydrogen desorption from aluminum hydride observed by magnetic resonance imaging", International Journal of Hydrogen Energy (2009) 34, 8067-8072.pdfPDF version

Fatehi, P., MacMillan, B., Ziaee, Z., Xiao, H.
"Qualitative Characterization of the Diffusion of Cationic-Modified PVA into the Cellulose Fiber Pores", Colloids and Surfaces A: Physicochemical and Engineering Aspects (2009) 348, 59-63.pdfPDF version

Vargas-Vasquez, S.M., Romero-Zerón, L.B. and MacMillan, B.
"Analysis of Synersis of HPAm/Cr(II) and HPAm/Cr(III) Acetate Gels Through 1H NMR, Bottle Testing, and UV-vis Spectrophotometry", Petroleum Science and Technology (2009) 27, 1727-1743.pdfPDF version

Sankey, M., Yang, Z. Gladden, L., Johns, M.L., Lister, D., Newling, B.
"SPRITE MRI of bubbly flow in a horizontal pipe", Journal of Magnetic Resonance (2009) 199, 126-135.pdfPDF version

Vargas-Vasquez, S.M., Romero-Zerón, L.B. and MacMillan, B.
"1H NMR, rheology, and bottle testing of HPAm/Cr(III) acetate micro gels", Petroleum Science and Technology (2009) 27:13:00, 1439-1453.pdfPDF version

Veliyulin, E., Aursand, I.G., Erikson, U., Balcom, B.J.
"Sodium MRI as a Tool for Optimization of Salting Processes", Magnetic Resonance in Food Science: Challenges in a Changing World (2009) Eds. Guðjónsdóttir, M., Belton, P., Webb, G., London, Royal Society of Chemistry, 251-256.pdfPDF version

Marangoni, A., MacMillan, B., Marty, S., Balcom, B.J.
"Spatial Mapping of Solid and Liquid Lipid in Chocolate", Magnetic Resonance in Food Science: Challenges in a Changing World (2009) Eds. Guðjónsdóttir, M., Belton, P., Webb, G., London, Royal Society of Chemistry, 105-112.pdfPDF version

Veliyulin, E., Egelandsdal, B., Marica, F. and Balcom, B.J.
"Quantitative 23Na Magnetic Resonance Imaging of Model Foods", Journal of Agricultural And Food Chemistry (2009) 57, 4091-4095.pdfPDF version

Li, L., Han, H. and Balcom, B.J.
"Spin Echo SPI Methods for Quantitative Analysis of Fluids in Porous Media", Journal of Magnetic Resonance (2009) 198, 252-260.pdfPDF version

Marble, A.E., LaPlante, G., Mastikhin, I.V. and Balcom, B.J.
"Magnetic Resonance Detection of Water in Composite Sandwich Structures", NDT&E International (2009) 42, 404-409.pdfPDF version

Romanenko, K., Cano-Barrita, F. de J. and Balcom, B.J.
"35Cl profiling using centric scan SPRITE with variable flip angle excitation", Journal of Magnetic Resonance (2009) 198, 24-30.pdfPDF version

Cano-Barrita, F. de J., Marble, A.E. Balcom, B.J., Garcia, J.C., Mastikhin, I.V., Thomas, M.D.A. and Bremner, T.W.
"Embedded NMR sensors to monitor evaporable water loss caused by hydration and drying in portland cement mortar", Cement and Concrete Research (2009) 39, 324-328.pdfPDF version

Li, L., Chen, Q., Marble, A.E., Romero-Zerón, L., Newling, B. and Balcom, B.J.
"Flow imaging of fluids in porous media by magnetization prepared centric-scan SPRITE", Journal of Magnetic Resonance (2009) 197, 1-8.pdfPDF version

Coarna, C. and Newling, B.
"Short, Shaped Pulses in a Large Magnetic Field Gradient", Journal of Magnetic Resonance (2009) 196, 127-132.pdfPDF version

2008

Mastikhin, I.V., Newling, B.
"Dynamics of dissolved gas in a cavitating fluid", Physical Review E (2008) 199, 78-6-066316 Part 2.pdfPDF version

Veliyulin, E., Mastikhin, I., Marble, A. and Balcom, B.
"Rapid Determination of the Fat Content in Packaged Dairy Products by Unilateral NMR", Journal of the Science of Food and Agriculture (2008) 88, 2563-2567.pdfPDF version

Feng, X., Balcom, B.J., Thomas, M.D.A. and Bremner, T.W.
"Na and Li Ion Diffusion in Modified ASTM C 1260 Test by Magnetic Resonance Imaging (MRI)", Cement and Concrete Research (2008) 38, 1409-1415.pdfPDF version

Green, D., Dick, J., McAloon, M., Cano-Barrita, F. de J., Burger, J. and Balcom, B.
"Oil/Water Imbibition and Drainage Capillary Pressure Determined by MRI on a Wide Sampling of Rocks", Society of Core Analysts, Abu Dhabi, UAE 29 October-2 November, 2008, 12 pages.pdfPDF version

Ouriadov, A., Newling, B. and Batchelor, S.
"Pulsed Field Gradient NMR Study of the Effect of Charge and Hydrophobicity on Diffusion in the Supramolecular Structure of Wet Cotton", Journal of Physical Chemistry C (2008) 112(40), 15860-15864.pdfPDF version

Zhang, Z., Marble, A.E., MacMillan, B., Promislow, K., Martin, J., Wang, H., and Balcom, B.J.
"Spatial and temporal mapping of water content across Nafion membranes under wetting and drying conditions", Journal of Magnetic Resonance (2008) 194, 245-253.pdfPDF version

Cano-Barrita, F. de J., Balcom, B., McAloon, M., Green, D. and Dick, J.
"Capillary Pressure Measurement on Cores by MRI", Journal of Petroleum Technology August 2008, 63-66.pdfPDF version

Zhang, J., MacGregor, R.P. and Balcom, B.J.
"Liquid Crystal Diffusion in Thin Films Investigated by PFG Magnetic Resonance and Magnetic Resonance Imaging", Chemical Physics Letters (2008) 461, 106-110.pdfPDF version

Petrov, O., Hay, J., Mastikhin, I. and Balcom, B.J.
"Fat and Moisture Content Determination with Unilateral NMR", Food Research International (2008) 41, 758-764.pdfPDF version

Zhang, Z., Martin, J., Wu, J., Wang, H., Promislow, K. and Balcom, B.J.
"Magnetic Resonance Imaging of Water Content across the Nafion Membrane in an Operational PEM Fuel Cell", Journal of Magnetic Resonance (2008) 193, 259-266.pdfPDF version

MacMillan, B., Hickey, H., Newling, B., Ramesh, M. and Balcom, B.
"Magnetic Resonance Measurements of French Fries to Determine Spatially Resolved Oil and Water Content", Food Research International (2008) 41, 676-681.pdfPDF version

Green, D., Gardner, J., Balcom, B.J., McAloon, M.J. and Cano-Barrita, F. de J.
"Comparison Study of Capillary Pressure Curves Obtained Using Traditional Centrifuge and Magnetic Resonance Imaging Techniques", SPE Improved Oil Recovery Symposium, Tulsa, Oklahoma, U.S.A., 19-23 April 2008, 11 pages.pdfPDF version

Vargas-Vasquez, S.M., Romero-Zerón, L.B. and MacMillan, B.
"Effect of Cr(III) Acetate Concentration on the 1H NMR Behavior of HPAm/Cr(III) Acetate Gels", International Journal of Polymer Analysis and Characterization (2008) 13(3), 163-179.pdfPDF version

Cano-Barrita, F. de J., Balcom, B., McAloon, M., Green, D. and Dick, J.
"Capillary Pressure Measurement in Petrolem Reservoir Cores with MRI", Offshore Technology Conference, Houston, Texas, 5-8 May 2008, 11 pages.pdfPDF version

LaPlante, G., Ouriadov, A.V., Lee-Sullivan, P. and Balcom, B.J.
"Anomalous Moisture Diffusion in an Epoxy Adhesive Detected by Magnetic Resonance Imaging", Journal of Applied Polymer Science (2008) 109, 1350-1359.pdfPDF version

Newling, B.
"Gas Flow Measurements by NMR", Progress in Nuclear Magnetic Resonance Spectroscopy (2008) 52, 31-48.pdfPDF version

2007

Green, D., Dick, J., Gardner, J., Balcom, B. and Zhou, B.
"Comparison Study of Capillary Pressure Curves Obtained Using Traditional Centrifuge and Magnetic Resonance Imaging Techniques", Society of Core Analysts, Calgary, Alberta, Canada 9-14 September 2007, 12 pages.pdfPDF version

Marica, F., Balcom, B., Mayer, K. and Al, T.
"MRI Determination of Spatially Resolved Tracer Distributions in a Rock Matrix Diffusion Experiment ", Proceedings of the 60th Canadian Geotechnical Conference & 8th Joint CGS/IAH-CNC Groundwater Conference, Ottawa, Ontario, 21-24 October 2007, 6 pages.pdfPDF version

Rioux, J., Halse, M., Aubanel, E., Balcom, B., Kaffanke, J., Romanzetti, S., Dierkes, T., and Shah, N.
"An Accurate Non-Uniform Fourier Transform for SPRITE Magnetic Resonance Imaging Data", ACM Transactions on Mathematical Software (2007) 33(3), Article 16.pdfPDF version

Marble, A.E., Mastikhin, I.V., Colpitts, B.G., and Balcom, B.J.
"Designing static fields for unilateral magnetic resonance with the scalar potential approach", IEEE Transactions on Magnetics (2007) 43, 1903-1911.pdfPDF version

Li L., Marica F., Chen Q., MacMillan B., Balcom B.J.
"Quantitative Discrimination of Water and Hydrocarbons in Porous Media by Magnetization Prepared Centric-scan SPRITE", Journal of Magnetic Resonance (2007) 186, 282-292.pdfPDF version

Marble, A.E., Mastikhin, I.V., Colpitts, B.G., Balcom, B.J.
"A Compact Permanent Magnet Array With a Remote Homogenous Field", Journal of Magnetic Resonance (2007) 186, 100-104.pdfPDF version

Peemoeller, H., Stanley, J.A., MacMillan, M.B., Weglarz, W.P. Bennett, J.C., Corbett, M. Hawton, J.M., Holly, R.
"Hydration study of homopolypeptides by 2H NMR", Biopolymers (2007) 86(1), 41965.pdfPDF version

Vargas-Vasquez, S.M., Romero-Zerón L.B., MacMillan, B.M.
"1H NMR Characterization of HP Am/Cr(III) acetate polymer gel components", International Journal of Polymer Analysis and Characterization (2007) 12(2), 115-129.pdfPDF version

2006

Marble, A.E., LaPlante, G., Mastikhin, I.V., Colpitts, B.G., and Balcom, B.J.
"A Unilateral Magnetic Resonance Moisture Sensor for Aerospace Composites", IEEE Canadian Conference on Electrical and Computer Engineering, Ottawa, Canada, 2006, May 7-10, 4 pages.pdfPDF version

Marble, A.E., Mastikhin, I.V., Colpitts, B.G., and Balcom, B.J.
"A constant gradient unilateral magnet for near-surface MRI profiling", Journal of Magnetic Resonance (2006) 183, 240-246.pdfPDF version

Chen, Q., Hickey, H. and Balcom, B.J.
"A Single-Shot Method for Determining Drainage and Imbibition Capillary Pressure Curves", Society of Core Analysts, Trondheim, Norway, 12-16 September 2006, 13 pages.pdfPDF version

Chen, Q., Rack, F. and Balcom, B.J.
"Quantitative Magnetic Resonance Imaging Methods for Core Analysis" in "New Ways of looking at Sediment Cores and Core Data", Geological Society Special Publication (2006) 267, 193-207.pdfPDF version

Khrapitchev, A.A., Newling, B. and Balcom, B.J.
"Centric-scan SPRITE Magnetic Resonance Imaging with Prepared Magnetisation", Journal of Magnetic Resonance (2006) 181, 271-279.pdfPDF version

Chen, Q. and Balcom, B.J.
"A Single-Shot Method for Capillary Pressure Curve Measurement Using Centrifuge and Quantitative Magnetic Resonance Imaging", SPE 100059, 2006 SPE/DOE Symposium on Improved Oil Recovery, Tulsa, Oklahoma, U.S.A., 22-26 April 2006, 8 pages.pdfPDF version

Stoch, G. J. and Balcom, B.J.
"Does a K-Space Span Limitation Affect MRI Resolution?", Concepts in Magnetic Resonance Part B (Magnetic Resonance Engineering) (2006) 29B(2), 55-61.pdfPDF version

Hickey, H., MacMillan B., Newling, B., Ramesh, M., Eijck, P.V. and Balcom, B.
"Magnetic Resonance Relaxation Measurements to Determine Oil and Water Content in Fried Foods", Food Research International (2006) 39, 612-618.pdfPDF version

Beyea, S.D., Bremner T.W. and Balcom, B.J.
"Minimization of Diffusive Attenuation in T2-Weighted NMR Images of Porous Solids using turboSPI", Solid State Nuclear Magnetic Resonance (2006) 29, 267-271.pdfPDF version

Young, J.J., Bremner, T.W., Thomas, M.D.A. and Balcom, B.J.
"Pure Phase Encode MRI of Concrete Building Material" in "Nuclear Magnetic Resonance Imaging in Chemical Engineering", Eds. Stapf, S. and Han, S., Wiley-VCH, Weinheim, Germany, 2006.pdfPDF version

Romanzetti, S., Halse, M., Kaffanke, J., Zilles, K., Balcom, B.J. and Shah, N.J.
"A comparison of three SPRITE techniques for the quantitative 3D imaging of the 23Na spin density on a 4T whole-body machine", Journal of Magnetic Resonance (2006) 179, 56-64.pdfPDF version

Khrapitchev, A.A., Newling, B. and Balcom, B.J.
"Sectoral sampling in centric-scan SPRITE magnetic resonance imaging", Journal of Magnetic Resonance (2006) 178, 298-306.pdfPDF version

Marica, F., Chen, Q., Hamilton, A., Hall, C., Al, T. and Balcom, B.J.
"Spatially Resolved Measurement of Rock Core Porosity", Journal of Magnetic Resonance (2006) 178, 136-141.pdfPDF version

Kaffanke, J., Dierkes, T., Romanzetti, S., Halse, M., Rioux, J., Leach, M.O., Balcom, B.J. and Shah, N.J.
"Application of the chirp z-transform to MRI data", Journal of Magnetic Resonance (2006) 178, 121-128.pdfPDF version

Deka, K., MacMillan M.B., Ouriadov, A.V., Mastikhin, I.V., Young, J.J., Glover, P.M., Ziegler, G.R. and Balcom, B.J.
"Quantitative Density Profiling with Pure Phase Encoding and a Dedicated 1D Gradient", Journal of Magnetic Resonance (2006) 178, 25-32.pdfPDF version

Deka, K., MacMillan B., Ziegler, G.R., Marangoni, A.G., Newling, B. and Balcom, B.J.
"Spatial mapping of solid and liquid lipid in confectionery products using a 1D centric SPRITE MRI technique", Food Research International (2006) 39(3), 365-371.pdfPDF version

2005

MacMillan, B., Burke, B., Balcom, B. and Ziegler, G.
"Phantom Materials for Single Point Imaging Pulse Sequences", Solid State Nuclear Magnetic Resonance (2005) 28, 106-110.pdfPDF version

Mastikhin, I.V. and Newling, B.
"MRI measurements of acoustically cavitated fluid in a standing wave", Physical Review E 72, 1 (2005 ).pdfPDF version

Feng, X., Thomas, M.D.A., Bremner, T.W., Balcom, B.J. and Folliard, K.J.
"Studies on Lithium Salts to Mitigate ASR-induced Expansion in New Concrete: A Critical Review", Cement and Concrete Research (2005) 35, 1789-1796.pdfPDF version

Glover, P.M., Newling, B., Poirier, C. and Balcom, B.J.
"A Novel High Temperature 1H NMR Imaging Probe for Combustion Studies: The Behaviour of both a Lit and Unlit Methane Gas Jet", Journal of Magnetic Resonance (2005) 176, 79-86.pdfPDF version

Zhang, Z.H., Ouriadov, A.V., Willson, C. and Balcom, B.J.
"Membrane Gas Diffusion Measurements with MRI ", Journal of Magnetic Resonance (2005) 176, 215-222.pdfPDF version

Belonogov, A., Marica, F., Lawfield, A., Butler, K.E., Chen, Q., Gingras, M. and Balcom, B.J.
"Magnetic Resonance Imaging of porosity Heterogeneity in Bioturbated Sandstone from the White Rose Reservoir, Atlantic Canada", SCA 2005-60, Proceedings of the International Symposium of the Society of Core Analysts, Toronto, Ontario 21-25 August 2005.pdfPDF version

Chen, Q., Butler, K.E., Gingras, M.K. and Balcom, B.J.
"A Mechanism Study of Co-Current and Counter-Current Imbibition Using New Magnetic Resonance Techniques", SCA 2005-38, Proceedings of the International Symposium of the Society of Core Analysts, Toronto, Ontario 21-25 August 2005.pdfPDF version

Chen, Q. and Balcom, B.J.
"Capillary Pressure Curve Measurement Using a Single-Moderate-Speed Centrifuge and Quantitative Magnetic Resonance Imaging", SCA 2005-44, Proceedings of the International Symposium of the Society of Core Analysts, Toronto, Ontario 21-25 August 2005.pdfPDF version

Chen, Q., Marble, A.E., Colpitts, B.G. and Balcom, B.J.
"The internal magnetic field distribution, and single exponential magnetic resonance free induction decay, in rocks", Journal of Magnetic Resonance (2005) 175, 300-308.pdfPDF version

Chen, Q. and Balcom, B.J.
"Measurement of Rock Core Capillary Pressure Curves Using a Single-Speed Centrifuge and One Dimensional Magnetic Resonance Imaging", Journal of Chemical Physics (2005) 122, 214720.pdfPDF version

Cheng, Y., Huang, Q.L., Eic, M. and Balcom, B.J.
"CO2 Dynamic Adsorption/Desorption on Zeolite 5A studied by 13C Magnetic Resonance Imaging", Langmuir (2005) 21, 4376-4381.pdfPDF version

LaPlante, G., Marble, A.E., MacMillan, B., Lee-Sullivan, P., Colpitts, B.G. and Balcom, B.J.
"Detection of Water Ingress in Composite Sandwich Structures: a Magnetic Resonance Approach", NDT&E International (2005) 38, 501-507.pdfPDF version

Chen, Q., Halse, M. and Balcom, B.J.
"Centric Scan SPRITE for spin density imaging of short relaxation time porous materials ", Magnetic Resonance Imaging (2005) 23, 263-266.pdfPDF version

Marble, A.E., Mastikhin, I.V., Colpitts, B.G., and Balcom, B.J.
"An analytical methodology for magnetic field control in unilateral NMR", Journal of Magnetic Resonance (2005) 174, 78-87.pdfPDF version

Rouison, D., Sain, M., Couturier, M., MacMillan, B. and Balcom, B.J.
"Water absorption of hemp fiber/unsaturated polyester composites", Polymer Composites (2005) 26, 509-525.pdfPDF version

Bremner, T.W., Cano-Barrita, F. de J., Balcom, B.J., Ĺ elih, J. and Sousa, A.C.M.
"The Gravimetric and Magnetic Resonance Imaging Techniques Used to Identify Appropriate Curing Regimes for Concrete in Hot Dry Climate", Invited paper for publication in Proceedings of the Raymundo Rivera International Symposium on Durability of Concrete, Monterrey, Mexico, May 12 & 13, 2005, 20 pages.pdfPDF version

Cano-Barrita, F. de J., Bremner, T.W. and Balcom, B.J.
"Water Absorption of High Performance Concrete", Invited paper for publication in Proceedings of the Raymundo Rivera International Symposium on Durability of Concrete, Monterrey, Mexico, May 12 & 13, 2005, 27 pages.pdfPDF version

Cheng, Y., MacMillan, M.B., MacGregor, R.P. and Balcom, B.J.
"Direct Detection of Hydrocarbon Displacement in a Model Porous Soil with Magnetic Resonance Imaging", Analytical Chemistry (2005) 77, 1824-1830.pdfPDF version

Mastikhin, I.V.
"Rapid determination of RF pulse flip angle and spin-lattice relaxation time for materials imaging", Journal of Magnetic Resonance (2005) 172, 231-237.pdfPDF version

2004

Newling, B., Poirier, C. C., Zhi, Y., Rioux, J. A., Coristine, A.J., Roach, D. and Balcom, B.J.
"Velocity Imaging of Highly Turbulent Gas Flow", Physical Review Letters (2004) 93, 154503.pdfPDF version

Young, J.J., Szomolanyi, P., Bremner, W. T. and Balcom, B.J.
"Magnetic Resonance Imaging of Crack Formation in Hydrated Cement Paste Material", Cement and Concrete Research (2004) 34, 1459-1466.pdfPDF version

Feng, X., Young, J.J., Thomas, M.D.A., Balcom, B.J. and Bremner, T.W.
"Lithium Measurements by Magnetic Resonance Imaging and Pore Solution Expression", Proceedings of the 12th International Conference on Alkali-Aggregate Reaction in Concrete, Beijing, China, October 15-19, 2004, 505-511.pdfPDF version

Cano-Barrita, F. de J., Bremner, T.W., Balcom, B.J., MacMillan, M.B. and Langley, W.S.
"Moisture Distribution in Drying Ordinary and High Performance Concrete Cured in a Simulated Hot Dry Climate", Materials and Structures (2004) 37, 522-531.pdfPDF version

Ouriadov, A.V., MacGregor, R.P. and Balcom B.J.
"Thin Film MRI - High Resolution Depth Imaging with a Local Surface Coil and Spin Echo SPI", Journal of Magnetic Resonance (2004) 169, 174-186.pdfPDF version

Halse, M., Rioux, J., Romanzetti, S., Kaffanke, J., MacMillan, B., Mastikhin, I.V., Shah, N.J., Aubanel, E. and Balcom, B.J.
"Centric Scan SPRITE Magnetic Resonance Imaging: Optimization of SNR, resolution and relaxation time mapping", Journal of Magnetic Resonance (2004) 169, 102-117.pdfPDF version

Young, J.J., Balcom, B.J., Bremner, T.W., Thomas, D.A. and Deka, K.
"A Magnetic Resonance Imaging Technique to Determine Lithium Distribution in Mortar" in ""Recent Advances in Concrete Technology, Seventh Canmet/ACI", (2004) 231-238.pdfPDF version

Cano-Barrita, F. de J., Bremner, T.W. and Balcom, B.J.
"Use of Magnetic Resonance Imaging to Study Internal Moist Curing in Concrete Containing Saturated Lightweight Aggregate" in "High Performance Structural Lightweight Concrete", ACI Special Publication 218 (2004) 155-176.pdfPDF version

Marble, A.E., Mastikhin, I.V., MacGregor, R.P., Akl, M., LaPlante, G., Colpitts, B.G., Lee-Sullivan, P. and Balcom, B.J.
"Distortion Free Single Point Imaging of Multi-layered Composite Sandwich Panel Structures", Journal of Magnetic Resonance (2004) 168, 164-174.pdfPDF version

Cano-Barrita, F. de J., Balcom, B.J. and Bremner, T.W.
"Non-Destructive Determination of Chloride and Sodium Distribution in Portland Cement Mortar", International Conference on Durability of High Performance Concrete, Essen, Germany, September 21-24, 2004, 351-360.pdfPDF version

2003

Newling, B. and Batchelor, S.N.
"Pulsed Field Gradient NMR Study of the Diffusion of H2O and Polyethylene Glycol Polymers in the Supramolecular Structure of Wet Cotton", Journal of Physical Chemistry B (2003) 107, 12391-12397.pdfPDF version

Halse, M., Goodyear, D.J., MacMillan, B., Szomolanyi, P., Matheson, D. and Balcom, B.J.
"Centric Scan SPRITE Magnetic Resonance Imaging", Journal of Magnetic Resonance (2003) 165, 219-229.pdfPDF version

Chen, Q., Gingras, M.K. and Balcom, B.J.
"A magnetic resonance study of pore filling processes during spontaneous imbibition in Berea sandstone", Journal of Chemical Physics (2003) 119, 9609-9616.pdfPDF version

Beyea, S.D., Balcom, B.J., Bremner, T.W., Armstrong, R.L. and Grattan-Bellew, P.E.
"Detection of Drying-Induced Microcracking in Cementitious Materials with Space-Resolved 1H Nuclear Magnetic Resonance Relaxometry", Journal of the American Ceramic Society (2003) 86, 800-805.pdfPDF version

Goodyear, D.J., Shea, M., Beyea, S.D., Shah, N.J. and Balcom, B.J.
"Single Point Measurements of Magnetic Field Gradient Waveform", Journal of Magnetic Resonance (2003) 163, 41646.pdfPDF version

Cano-Barrita, F. de J., Bremner, T.W. and Balcom, B.J.
"Effects of curing temperature on moisture distribution, drying and water absorption in compacting concrete", Magazine of Concrete Research (2003) 55, 517-524.pdfPDF version

Balcom, B.J., Barrita, J.C., Choi, C., Beyea, S.D., Goodyear, D.J. and Bremner, T.W.
"Single-point magnetic resonance imaging (MRI) of cement based materials", Materials and Structures (2003) 36, 166-182.pdfPDF version

Lees, T.J. and Balcom, B.J.
"Magnetic Resonance Imaging of Spatially Resolved Acrylamide Photopolymerization", Magnetic Resonance in Chemistry (2003) 41, 229-236.pdfPDF version

Ziegler, G.R., MacMillan, B. and Balcom, B.J.
"Moisture migration in starch molding operations as observed by magnetic resonance imaging", Food Research International (2003) 36, 331-340.pdfPDF version

2002

Cano-Barrita, F. de J., Bremner, T.W., Balcom, B.J., McMillan, M.B. and Langley, W.S.
"Curing of High Performance Concrete in Hot Dry Conditions Studied by Magnetic Resonance Imaging", Supplementary paper given at ACI Fifth International Conference in Cancun, Mexico, December, 2002, 129-148.pdfPDF version

Gingras, M.K., MacMillan, B. and Balcom, B.J.
"Visualizing the internal physical characteristics of carbonate sediments with magnetic resonance imaging and petrography", Bulletin of Canadian Petroleum Geology (2002) 50, 363-369.pdfPDF version

Cano-Barrita, F. de J., Bremner, T.W., MacGregor, R.P., Balcom, B.J.
"Magnetic resonance imaging of 1H, 23Na, and 35Cl penetration in Portland cement mortar", Cement and Concrete Research (2002) 32, 1067-1070.pdfPDF version

Bär, Nils-Karsten, Balcom, B.J. and Ruthven, D.M.
"Direct Measurement of Transient Concentration Profiles in Adsorbent Particles and Chromatographic Columns by MRI", Industrial & Engineering Chemistry Research (2002) 41, 2320-2329.pdfPDF version

Bär, Nils-Karsten, Bauer, F. Ruthven, D.M. and Balcom, B.J.
"Direct and Indirect Observation of Coke Deposits on HZSM-5 by 1H NMR Imaging", Journal of Catalysis (2002) 208, 224-228.pdfPDF version

MacMillan, B., Halse, M., Schneider, M., Fardy, L., Chui, Y.H. and Balcom, B.J.
"Magnetic Resonance Imaging of Rigid Polymers at Elevated Temperatures with SPRITE", App. Magn. Reson. (2002) 22, 247-256.pdfPDF version

MacMillan, M.B., Schneider, M. H., Sharp, A.R. and Balcom, B.J.
"Magnetic Resonance Imaging of Water Concentration in Low Moisture Content Wood", Wood and Fiber Science (2002) 34, 276-286.pdfPDF version

Gingras, M.K., MacMillan, B., Balcom, B.J., Saunders, T. and Pemberton, S.G.
"Using Magnetic Resonance Imaging and Petrographic Techniques to Understand the Textural Attributes and Porosity Distribution in Macarinichnus-Burrowed Sandstone", J. Sedimentary Research (2002) 72, 552-558.pdfPDF version

Mastikhin, I.V., Mullally, H., MacMillan, B. and Balcom, B.J.
"Water content profiles with a 1D centric SPRITE acquisition", Journal of Magnetic Resonance (2002) 156, 122-130.pdfPDF version

Ciampi, E., Goerke, U., McDonald, P.J., Chambers, J.G. and Newling, B.
"Spatially-resolved magnetic resonance study of the dissolution interface between soaps and water", J. Phys. D: Appl. Phys. (2002) 35, 1271-1281.pdfPDF version

2001

Szomolanyi, P., Goodyear, D., Balcom, B.J. and Matheson, D.
"SPIRAL-SPRITE: a rapid single point MRI technique for application to porous media", Magn. Reson. Imaging (2001) 19, 423-428.pdfPDF version

Troutman, M.Y., Mastikhin, I.V., Balcom, B.J., Eads, T.M. and Ziegler, G.R.
"Moisture migration in soft-panned confections during engrossing and aging as observed by magnetic resonance imaging", J. Food Eng. (2001) 48, 257-267.pdfPDF version

Ciampi, E., Goerke, U., McDonald, P.J., Chambers, J. and Newling, B.
"Studies Of The Dissolution of Structured Surfactant Using Spatially Localised Double Quantum Filter and J-Cyclic-Cross Polarisation Edited NMR", Magn. Reson. Imaging (2001) 19, 572.pdfPDF version

Gillies, D.G., Newling, B. and Randall, E.W.
"Phosporus-31 Solid-State NMR in High Field-Gradients: Prospects For Imaging Bone Using The Long Echo-Train Summation Technique (LETS)", Journal of Magnetic Resonance (2001) 151, 235-241.pdfPDF version

Hopkinson, I., Jones, R.A.L., McDonald, P.J., Newling, B., Lecat, A. and Livings, S.
"Water Ingress Into Starch and Sucrose : Starch Systems", Polymer (2001) 42, 4947-4956.pdfPDF version

Newling, B., Ward, D. and Vijayakrishnan, V.
"Stray Field Magnetic Resonance Imaging (STRAFI) of Water Transport in Ceramic Substrates", J. Porous Mat. (2001) 8, 193-199.pdfPDF version

2000

Bär, Nils-Karsten, Balcom, B.J. and Ruthven, D.M.
"Direct Measurement of Transient Concentration Profiles in Molecular Sieve Particles and Columns by MRI" in "Adsorption Science and Technology ", Ed. Duong D Do, Singapore ; River Edge, N.J. : World Scientific, 2000.pdfPDF version

Choi, C., Balcom, B.J., Beyea, S.D., Bremner, T.W., Grattan-Bellew, P.E. and Armstrong, R.L.
"Spatially resolved pore-size distribution of drying concrete with magnetic resonance imaging", J. Appl. Phys. (2000) 88, 3578-3581.pdfPDF version

Beyea, S.D., Balcom, B.J., Mastikhin, I.V., Bremner, T.W., Armstrong, R.L. and Grattan-Bellew, P.E.
"Imaging of Heterogeneous Materials with a Turbo Spin Echo Single-Point Imaging Technique", Journal of Magnetic Resonance (2000) 144, 255-265.pdfPDF version

Prado, P.J., Bluemich, B. and Balcom, B.J.
""Magnetic Resonance Techniques" in "Spectroscopy in Process Analysis"", Ed. John Chalmers, Sheffield Academic Press, 2000.pdfPDF version

1999

Prado, P.J., Balcom, B.J., Mastikhin, I.V., Cross, A.R., Armstrong, R.L. and Logan, A.
"Magnetic Resonance Imaging of Gases: A SPRITE Study", Journal of Magnetic Resonance (1999) 137, 324-332.pdfPDF version

Peemoeller, H., MacMillan, M.B., Weglarz, W.P., Schreiner, L.J. and Thompson, R.T.
"Intrinsic Proton Relaxation Parameters of Hydrated Polyglycine from Two-Dimensional Time Domain NMR", Biopolymers (1999) 50, 630-640.pdfPDF version

MacMillan, B., Sharp, A.R. and Armstrong, R.L.
"An NMR Investigation of Water Absorbed in Nafion", Polymer (1999) 40, 2471-2480.pdfPDF version

MacMillan, B., Sharp, A.R. and Armstrong, R.L.
"NMR Relaxation in Nafion - the Low Temperature Regime", Polymer (1999) 40, 2481-2485.pdfPDF version

Beyea, S.D., Balcom, B.J., Mastikhin, I.V., Bremner, T.W., Armstrong, R.L. and Grattan-Bellew, P.E.
"Development of a New MRI Technique for Imaging Heterogeneous Materials: TurboSPI", Physics in Canada (November/December 1999 ),348-350. CAP Lumonics Student Prize Lecture.pdfPDF version

Prado, P.J., Balcom, B.J. and Jama, M.
"Single-Point Magnetic Resonance Imaging Study of Water Adsorption in Pellets of Zeolite 4A", Journal of Magnetic Resonance (1999) 137, 59-64.pdfPDF version

Mastikhin, I.V., Balcom, B.J., Prado, P.J. and Kennedy, C.B.
"SPRITE MRI with Prepared Magnetization and Centric k Space Sampling", Journal of Magnetic Resonance (1999) 136, 159-168.pdfPDF version

Mastikhin, I.V., Teslenko, V.S., Gorchakov, V.N., Nikolin, V.P. and Kolosova, N.G.
"Application of NMR-Tomography and histological analysis to study cavitation processes induced by ultrasonic shock waves in biological objects", B. Exp. Biol. Med. (1999) 127, 653-655.pdfPDF version

Hart, T.D., Chamberlain, A.H.L., Lynch, J.M., McDonald, P.J. and Newling, B.
"A Stray Field Magnetic Resonance Study of Water Diffusion in Bacterial Exopolysaccharides", Enzyme Microb. Tech. (1999) 24, 339-347.pdfPDF version

1998

McDonald, P.J. and Newling, B.
"Stray Field Magnetic Resonance Imaging", Rep. Prog. Phys. (1998) 61, 1441-1493.pdfPDF version

Kennedy, C.B., Balcom, B.J., Mastikhin, I.V.
"Three Dimensional Magnetic Resonance Imaging of Rigid Polymeric Materials Using Single Point Ramped Imaging with T1 Enhancement (SPRITE)", Can. J. Chem. (1998) 76, 1753-1765.pdfPDF version

Balcom, B.J.
"SPRITE Imaging of Short Relaxation Time Nuclei" in "Spatially Resolved Magnetic Resonance: Methods. Materials, Medicine, Biology, Rheology, Geology, Ecology, Hardware", Eds. P. Bluemler, B. Bluemich, R. Botto, E. Fukushima, Wiley/VCH, Weinheim, Germany, 1998.pdfPDF version

Beyea, S.D., Balcom, B.J., Bremner, T.W., Prado, P.J., Cross, A.R., Armstrong, R.L. and Grattan-Bellew, P.E.
"The Influence of Shrinkage-Cracking on the Drying Behaviour of White Portland Cement Using Single-Point Imaging (SPI)", Solid State NMR (1998) 13, 93-100.pdfPDF version

Beyea, S.D., Balcom, B.J., Prado, P.J., Cross, A.R., Kennedy, C.B., Armstrong, R.L. and Bremner, T.W.
"Relaxation Time Mapping of Short T2* Nuclei with Single-Point Imaging (SPI) Methods", Journal of Magnetic Resonance (1998) 135, 156-164.pdfPDF version

Prado, P.J., Balcom, B.J., Beyea, S.D., Armstrong, R.L., Bremner, T.W. and Grattan-Bellew P.E.
"Concrete/Mortar Water Phase Transition Studied by Single-Point MRI Methods", Magnetic Resonance Imaging (1998) 16, 521-523.pdfPDF version

Prado, P.J., Balcom, B.J., Beyea, S.D., Bremner, T.W., Armstrong, R.L., Pishe, R. and Grattan-Bellew, P.E.
"Spatially Resolved Relaxometry and Pore Size Distribution by Single Point MRI Methods. Porous Media Calorimetry", J. Phys. D (1998) 31, 2040-2050.pdfPDF version

Rack, F.R., Balcom, B.J., MacGregor, R.P. and Armstrong, R.L.
"Magnetic resonance imaging of the Lake Agassiz-Lake Winnipeg Transition", Journal of Paleolimnology (1998) 19, 255-264.pdfPDF version

Beyea, S.D., Balcom, B.J., Bremner, T.W., Prado, P.J., Green, D.P., Armstrong, R.L. and Grattan-Bellew, P.E.
"Magnetic Resonance Imaging and Moisture Content Profiles of Drying Concrete", Cement and Concrete Research (1998) 28, 453-463.pdfPDF version

Prado, P.J., Balcom, B.J., Beyea, S.D., Bremner, T.W., Armstrong, R.L. and Grattan-Bellew, P.E.
"Concrete Freeze-Thaw as Studied by Magnetic Resonance Imaging", Cement and Concrete Research (1998) 28, 261-270.pdfPDF version

1997

Beyea, S.D., Bremner, T.W., Prado, P.J., Balcom, B.J., Gratten-Bellew, P.E. and Armstrong, R.L.
"Magnetic Resonance Imaging (MRI) of Moisture Distribution in Concrete", Canadian Society for Civil Engineering Conference (May 27-30, 1997, Sherbrooke QC, Canada).pdfPDF version

Bohris, A.J., Goerke, U., McDonald, P.J. et al.
"A Broad Line NMR and MRI Study of Water and Water Transport in Portland Cement Pastes", Magn. Reson. Imaging (1998) 16, 455-461.pdfPDF version

Bohris, A.J., Newling, B., McDonald, P.J., Raoof, A. and Tran, N.L.
"A Broad Line Nuclear Magnetic Resonance Study of Water Absorption and Transport in Fibrous Cement Roofing Tiles", J. Mat. Sci. (1998) 33, 859-867.pdfPDF version

Prado, P.J., Balcom, B.J., Beyea, S.D., Armstrong, R.L. and Bremner, T.W.
"Concrete Thawing Studied by Single-Point Ramped Imaging", Solid State NMR (1997) 10, 41647.pdfPDF version

Balcom, B.J., Fischer, A.E., Carpenter, T.A. and Hall, L.D.
"MRI Measurements of Paramagnetic Tracer Ion Diffusion", Bull. Mag. Res. (1997) 18, 204-210.pdfPDF version

Mastikhin I.V., Teslenko V.S. and Ananchenko G.S.
"Polymerisation of acrylamide by shock-acoustic waves in liquid", Acoustics of Inhomogeneous Media (1997) 112, 176-184.pdfPDF version

Newling, B., Gibbs, S., Derbyshire, J., Xing, D., Hall, L., Haycock, D., Frith, W. and Ablett, S.
"Comparison of MRI Velocimetry with Computational Fluid Dynamics", J. Fluids Eng. (1997) 119, 103-109.pdfPDF version

Newling, B., Gibbs, S., Hall, L., Haycock, D., Frith, W. and Ablett, S.
"Chemically Resolved NMR Velocimetry", Chem. Eng. Sci. (1997) 52, 2059-2072.pdfPDF version

Newling, B., Glover, P.M., Lane, D.M., Keddie, J.L. and McDonald, P.J.
"Concentration Profiles in Creaming Oil-in-Water Emulsions Determined with Stray Field Magnetic Resonance Imaging", Langmuir (1997) 13, 3621-3626.pdfPDF version

Glover, P.M., McDonald, P.J. and Newling, B.
"Stray Field Imaging of Planar Films Using a Novel Surface Coil", Journal of Magnetic Resonance (1997) 126, 207-212.pdfPDF version

1996

Balcom, B.J. and Petersen, N. O.
"Nitrobenzoxadiazole-labeled Polyisoprenoid Alcohols", Can. J. Chem. (1996) 74, 2531-2535.pdfPDF version

Balcom, B.J., MacGregor, R.P., Beyea, S.D., Green, D.P., Armstrong, R.L. and Bremner, T.W.
"Single Point Ramped Imaging with T1 Enhancement (SPRITE)", Journal of Magnetic Resonance A (1996) 123, 131-134.pdfPDF version

Balcom, B.J., Bogdan, M. and Armstrong R.L.
"Single Point Imaging of Gradient Rise, Stabilization and Decay", Journal of Magnetic Resonance A (1996) 118, 122-125.pdfPDF version

Green, D.P., Balcom, B.J. and Lees, T.J.
"Sensor Measurement and Experimental Control in Nuclear Magnetic Resonance Imaging", Rev. Sci. Instrum. (1996) 67, 102-107.pdfPDF version

Wise, R., Newling, B., Gates, A., Xing, D., Carpenter, T. and Hall, L.
"Measurement of Pulsatile Flow Using MRI and a Bayesian Technique of Probability Analysis", Magn. Reson. Imaging (1996) 14, 173-185.pdfPDF version

1995

Bogdan, M., Balcom, B.J., Bremner, T.W. and Armstrong, R.L.
"Single Point Imaging of Partially Dried, Hydrated White Portland Cement", Journal of Magnetic Resonance A (1995) 116, 266-269.pdfPDF version

Mastikhin, I.V., Lukzen, N.N., Zelentzov, E.L. and Sagdeev, R.Z.
"Increased MR Image Contrast by Correlation of Tissue Relaxation Properties", Magn. Reson. Med. (1995) 33, 832-837.pdfPDF version

Mastikhin, I.V., Nikolin, V.P., Teslenko, V.S., Zelentzov, E.L., Mayer, V. A., Salganik, R.I. and Dikalov, S.I.
"Treatment with Shock Waves Increases the Sensitivity of Tumor Cells to Cyclophosphamide", Doklady Biophysics (1995) 340-342, 14-16.pdfPDF version

Balcom, B.J., Lees, T.J., Sharp, A.R., Kulkarni, N.S. and Wagner, G.S.
"Diffusion in Fe(II/III) Radiation Dosimetry Gels Measured by Magnetic Resonance Imaging", Phys. Med. Biol. (1995) 40, 1665-1676.pdfPDF version

Fischer, A.E., Balcom, B.J., Fordham, E. J., Carpenter, T.A. and Hall, L.D.
"A Fast Inversion Recovery NMR Imaging Technique for Mapping Two-dimensional Tracer Diffusion and Dispersion in Heterogeneous Media", J. Phys. D (1995) 28, 384-397.pdfPDF version

Newling, B., Derbyshire, J., Carpenter, T., Xing, D. and Hall, D.
"Construction of Multiply Band-Selective, Self-Refocusing Pulses for Simultaneous, Spin-Echo, Multislice Imaging of Fluid Flow Using Pulsed Field Gradients", Journal of Magnetic Resonance B (1995) 108, 269-273.pdfPDF version

1994

Potter, K.P., Balcom, B.J., Carpenter, T.A. and Hall, L.D.
"The Gelation of Sodium Alginate with Calcium Ions Studied by Magnetic Resonance Imaging (MRI)", Carbohydrate Research (1994) 257, 117-126.pdfPDF version

1993

Balcom, B.J. and Petersen, N.O.
"Lateral Diffusion in Model Membranes is Independent of the Size of the Hydrophobic Region of Molecules", Biophys. J. (1993) 65, 630-637.pdfPDF version

Balcom, B.J., Fischer, A.E., Carpenter, T.A. and Hall, L.D.
"Diffusion in Aqueous Gels. Mutual Diffusion Coefficients Measured by One-Dimensional Nuclear Magnetic Resonance Imaging.", J. Am. Chem. Soc. (1993) 115, 3300-3305.pdfPDF version

1992

Balcom, B.J., Carpenter, T.A. and Hall, L.D.
"Spatial and Temporal Visualization of Two Aqueous Iron Oxidation-Reduction Reactions by Nuclear Magnetic Resonance Imaging", J. Chem. Soc. Chem. Comm. (1992) 4, 312-313.pdfPDF version

Balcom, B.J., Carpenter, T.A. and Hall, L.D.
"Spatial and Temporal Visualization of a pH-dependent Complexation Equilibrium by Nuclear Magnetic Resonance Imaging", Can. J. Chem. (1992) 70, 2693-2697.pdfPDF version

Balcom, B.J., Carpenter, T.A. and Hall, L.D.
"Methacrylic Acid Polymerization. Travelling Waves Observed by Nuclear Mangetic Resonance Imaging", Macromolecules (1992) 25, 6818-6823.pdfPDF version

1991

Balcom, B.J. and Petersen, N.O.
"Synthesis and Surfactant Behavior of an Unusual Cyclic Triester Based on a cis,cis-1,3,5-Cyclohexanetriol Headgroup", Langmuir (1991) 7, 2425-2427.pdfPDF version

1989

Balcom, B.J. and Petersen, N.O.
"Solvent Dependence of Carboxylic Acid Condensations with Dicyclohexylcarbodiimide", J. Org. Chem. (1989) 54, 1922-1927.pdfPDF version

1986

Ross, L., Barclay, C., Balcom, B.J. and Forrest, B.J.
"Phospholipid Inverted Micelles. Autoxidation Kinetics and 31P NMR Exchange Rates", J. Am. Chem. Soc. (1986) 108, 761-766.pdfPDF version

Patents Issued

"Probe and Sample Holder for Magnetic Resonance and Manetic Resonance Imaging" - Immersed RF Probe, Metal Core Holder
(US Patent: 10,481,114) - (Issued November 19, 2019)
Inventors - Mojtaba Shakerian, Bruce J. Balcompdf
PDF version

System and Method for Spatially Resolved T1-T2 Distribution Measurement
(US Patent: 10,473,601) - (Issued November 12, 2019)
Inventors - Sarah Vashaee, Benedict Newling, Bruce J. BalcompdfPDF version

"Spin echo SPI Methods for Quantitative Analysis of Fluids in Porous Media"
(European Patent: EP2310867 B1) - (Issued Oct. 3, 2018)
Inventors - Linqing Li, Bruce Balcom, Derrick Green, Oleg PetrovpdfPDF version

"Free Induction Decay Based Magnetic Resonance Imaging Methods" - FID SPI
(US Patent: 9,864,033) - (Issued January 9, 2018)
Inventors - Florin Marica, Bruce BalcompdfPDF version

"Magnetic Field Gradient Monitor and Magnetic Field Gradient Waveform Correction Apparatus and Methods" - Pre-equalization of Magnetic Field Gradient Waveforms
(US Patent: 9,829,554) - (Issued November 28, 2017)
Inventors - Fred Goora, Bruce BalcompdfPDF version

"Magnetic Resonance Imaging Apparatus and Method" - Metallic MR Compatible Core Holder
(CA Patent: 2 683 411) - (Issued July 18, 2017)
Inventors - Bruce Balcom, Derrick Green, Hui HanpdfPDF version

"Method of Sampling in Pure Phase Encode Magnetic Resonance Imaging" - Restricted Sampling
(US Patent: 9,702,953) - (Issued July 11, 2017)
Inventors - Bruce Balcom, Dan XiaopdfPDF version

"Spin echo SPI Methods for Quantitative Analysis of Fluids in Porous Media" - Hybrid SPRITE Profiles
(European Divisional Patent: EP2894490 B1) - (Issued September 14, 2016)
Inventors - Bruce Balcom, Michael Li, Oleg Petrov, Derrick GreenpdfPDF version

"Spatially Resolved Magnetic Resonance Spin-Spin Relaxation Distribution Measurement Methods" - DANTE T2 Measurement
(US Patent: 9,389,193) - (Issued July 12, 2016)
Inventors - Bruce Balcom, Oleg PetrovpdfPDF version

"Method of Magnetic Resonance Imaging Combining Phase and Frequency" - Hybrid Sprite
(US Patent: 9,304,179) - (Issued April 5, 2016)
Inventors - Bruce Balcom, Dan XiaopdfPDF version

"Spin echo SPI Methods for Quantitative Analysis of Fluids in Porous Media"
(US Patent: 9,018,950) - (Issued April 28, 2015)
Inventors - Linqing Li, Bruce Balcom, Derrick Green, Oleg PetrovpdfPDF version

"Methods of Radio Frequency Magnetic Field Mapping" -B1 Mapping
(US Patent: 8,890,527) - (Issued November 18, 2014)
Inventors - Bruce Balcom, Sarah Vashaee, Ben Newling, Bryce MacMillanpdfPDF version

"Methods and Apparatus for Measuring Capillary Pressure in a Sample"
(CA Patent: 2,524,993) - (Issued October 14, 2014)
Inventors - Quan Chen, Bruce BalcompdfPDF version

"Magnetic Resonance Apparatus and Method" - Metallic MR Compatible Core Holder
(US Patent: 8,791,695) - (Issued July 29, 2014)
Inventors - Bruce Balcom, Derrick Green, Hui HanpdfPDF version

"Probe, System and Method Suitable for Unilateral Nuclear Magnetic Resonance" - Embedded Magnet
(CA Patent: 2,600,990) - (Issued June 3, 2014)
Inventors - Andrew Marble, Josh Young, Igor Mastikhin, Bruce Balcom, Bruce ColpittspdfPDF version

"Magnetic Field Gradient Monitor Apparatus and Method"
(US Patent: 8,717,022) - (Issued May 6, 2014)
Inventors - Hui Han, Bruce BalcompdfPDF version

"Magnet Array" - 3 Magnet Array for Unilateral MR
(US Patent: 8,593,144) - (Issued November 26, 2013)
Inventors - Andrew Marble, Bruce Balcom, Bruce Colpitts, Igor MastikhinpdfPDF version

"Magnetic Field Generator Suitable for Unilateral Nuclear Magnetic Resonance and Method for Making Same: Continuation in Part" - Pole Piece Magnet Design
(US Patent: 8,237,440) - (Issued August 7, 2012)
Inventors - Bruce Balcom, Andrew Marble, Igor Mastikhin, Bruce ColpittspdfPDF version

"Methods and Apparatus for Measuring Capillary Pressure in a Sample"
(European Patent: EP1655617 B1) - (Issued Oct. 12, 2011)
Inventors - Quan Chen, Bruce BalcompdfPDF version

"MR-Bildgebungsverfahren ('SPRITE')"
(German Patent: DE102004060513) - (Issued June 22, 2011)
Inventors - Bruce Balcom, Meghan Halse, Sandro Romanzetti, Thomas Dierkes, Nadim Joni Shah, Joachim KaffankepdfPDF version

"Probe, System and Method Suitable for Unilateral Nuclear Magnetic Resonance" - Embedded Magnet
(US Patent: 7,733,091) - (Issued June 8, 2010)
Inventors - Andrew Marble, Josh Young, Igor Mastikhin, Bruce Colpitts, Bruce BalcompdfPDF version

"Methods Suitable for Measuring Capillary Pressure and Relative Permeability Curves of Porous Rocks" - Steady State Relative Permeability Measurement
(US Patent: 7,567,079) - (Issued July 28, 2009)
Inventors - Quan Chen, Bruce BalcompdfPDF version

"Methods and Apparatus for Measuring Capillary Pressure in a Sample"
(US Patent: 7,352,179) - (Issued April 1, 2008)
Inventors - Quan Chen, Bruce BalcompdfPDF version

"Sensor And Magnetic Field Apparatus Suitable For Use In Unilateral Nuclear Magnetic Resonance and Method For Making Same" - Pole Piece Magnet
(US Patent: 7,319,326) - (Issued Jan. 15, 2008)
Inventors - Bruce Balcom, Andrew Marble, Igor Mastikhin, Bruce ColpittspdfPDF version


Contact Information
The University of New Brunswick
Department of Physics
Bruce Balcom
bjb@unb.ca
Last update: October 2022